A reliable KiCad variant release makes the fitted population unambiguous in the bill of materials, placement data and assembly instructions. A DNP mark on a schematic is useful design intent, but the manufacturing team needs a consistent set of exported files for the exact configuration being ordered. Review that set before requesting components or starting assembly.
This article focuses on releasing fitted and do-not-populate parts on a shared board. It uses the KiCad 10.0 documentation as the software reference, checked on October 10, 2026. Other versions and third-party exporters can behave differently. Record your installed version and verify its actual exported files; do not assume that a similarly named checkbox in another tool produces the same result.
Define the assembly identity before changing flags
Give the board design, assembly revision and product configuration separate identifiers. For example, an industrial input module might use bare board revision C for both a standard assembly and a diagnostic assembly. The diagnostic build includes a connector and indicator components that the standard build omits. The shared board revision does not tell the assembler which population to build.
Write a release statement such as: board C, assembly A2, configuration DIAG, quantity 40. Use that identity in the purchase order, archive name and assembly drawing. An informal label such as latest or customer version is difficult to verify after an engineer changes the project or a purchasing team forwards only part of an email thread.
Before editing CAD data, make a small decision matrix with one row per affected reference. Include the intended population in each configuration, the approved part identifier when fitted, and the reason for the difference. This is a review aid rather than another uncontrolled BOM. Resolve disagreements in the design source, regenerate outputs and archive the approved matrix with the release evidence.
Understand what the software is being asked to represent
The KiCad 10.0 Schematic Editor manual describes variants as assembly overrides on a common design. The copper, netlist and outline remain shared. DNP and output-exclusion flags are independent. Variant data is defined in the schematic and transferred to the PCB through Update PCB from Schematic. The BOM exporter uses the active variant’s effective fields and flags.
Those distinctions matter during review. A location intentionally left empty is not the same engineering decision as a component that exists but is omitted from a particular purchasing report. Likewise, changing a part description cannot make an incompatible package fit an existing footprint. When a proposed option requires new copper or different pad geometry, review it as a board-design change rather than relying on the assembly name to conceal the difference.
A useful internal rule is that every exception must have an owner and a reason. A connector fitted by a later assembly operation needs a documented route. A non-purchased board feature needs an explanation for why it appears in an export. A deliberately empty resistor location needs a clear population state. Do not expect the manufacturing planner to infer these decisions from a blank part-number cell.
Check one representative component end to end
Start with a reference whose population changes between configurations. Follow it from the approved matrix to the schematic, the board, the BOM and the placement output. Also follow a reference that remains fitted in every configuration. These two checks expose both a filter that fails to remove optional parts and a filter that accidentally removes mandatory parts.
Repeat the check after synchronizing the board. Save the project first, inspect the proposed update and investigate unexpected changes. The aim is not simply to make both editors display the same configuration label. The effective component data and the manufacturing files must describe the same assembly. A screenshot is helpful evidence, but it does not replace inspecting the exported rows.
For projects with repeated circuit channels, choose examples from more than one channel. A reference in the first channel can be correct while another instance retains different data. The release reviewer should be able to identify the exact physical location, not just a generic library symbol or a shared value such as ten kilohms.
Export the BOM as a controlled build document
Decide whether the delivered BOM lists only fitted components or includes explicit DNP rows. Either convention can be understandable when agreed with the assembler. Problems arise when one team assumes absent means DNP while another assumes absent means accidentally omitted. State the convention in the release note and keep a complete internal population matrix for comparison.
Use enough fields to distinguish orderable parts. For fitted items, review manufacturer, manufacturer part number, package and any relevant approved alternatives. A shared resistance value alone is not a sufficient grouping key when tolerance, power rating or package differs. If grouped rows contain multiple references, expand them during review and check that the quantity agrees with the actual reference list.
Separate the per-board quantity from the procurement quantity. A BOM describing four identical resistors per assembly should not silently become a quantity of four hundred because someone is buying for one hundred boards. Procurement allowances, spare parts and attrition belong in the purchasing calculation with their own assumptions. Keep the engineering population easy to compare against the board.
Review placement filtering separately
The KiCad 10.0 PCB Editor manual documents a design-variant selection for position export and optional filtering of DNP and BOM-excluded footprints. It also describes SMD-only and through-hole-pad filters, coordinate units and origin settings. A footprint explicitly excluded from position files is omitted. Confirm the required convention with the assembler rather than treating one export preset as universal.
Consider a fitted through-hole connector assembled after SMT reflow. It belongs in the assembly definition even when the SMT machine file excludes it. A comparison that demands identical reference sets across every file would report this as an error. A better comparison classifies each reference by assembly operation and then tests it against the appropriate expected set.
Review the coordinate convention independently of population. Correctly removing DNP locations will not correct a wrong origin or misunderstood bottom-side rotation. Ask the assembler to review a recognizable polarized component and a known board feature in its own import preview. Keep any agreed conversion rule with the release package, and avoid making undocumented spreadsheet adjustments after the CAD export.
Work through a small reconciliation example
Consider an invented controller with these five relevant locations: U1 is always fitted; R10 and R11 are fitted only in the diagnostic configuration; J2 is a fitted connector installed manually; and TP1 is a copper test feature rather than a purchased component. Assume the agreed SMT position file contains only machine-placed components and the delivered BOM contains only purchased fitted parts.
For the diagnostic build, the fitted BOM contains U1, R10, R11 and J2. The machine-placement set contains U1, R10 and R11. J2’s absence from that file is explained by its manual operation. TP1 appears in neither purchasing nor machine-placement data, but remains available in the board and test documentation. For the standard build, R10 and R11 are additionally absent from both manufacturing sets.
The important check is not that the totals match. Suppose R10 disappears and an unrelated optional R12 appears instead. The row count can remain unchanged while the board population is wrong. Compare reference identities and effective part identifiers. Treat an unexplained extra reference as seriously as a missing one, because an unwanted component can alter circuit operation.
This example is a release-control exercise, not a demonstrated KiCad project or a factory case study. Apply its comparison method to your own reference sets and agreed assembly process. For a larger design, a reviewed comparison script or spreadsheet can help, provided the expected lists and transformation rules are preserved and somebody investigates every exception.
Keep assembly and test instructions aligned
A population change can affect more than purchasing. Removing an indicator may change a visual inspection step. Omitting an interface may require a different functional-test route. A configuration resistor may affect firmware behavior. Record these consequences in the assembly and test documents, rather than leaving the test team to discover that the expected feature is intentionally absent.
Use the same configuration identifier on the assembly drawing and test record. If the product is programmed during manufacturing, connect that identifier to the approved firmware release and programming instructions. Avoid a process in which an operator chooses firmware from memory based on whether a connector appears to be installed.
Review stencil and process implications when optional locations are involved. A common copper design does not establish that every configuration should use identical paste-printing or inspection settings. Raise the affected locations with the assembly engineer and document the agreed treatment. Do not invent a blanket rule that all DNP pads must receive paste or that all must be blocked.
Make regeneration reproducible
Archive the source project, software version, configuration name, output settings, released files and approval note together. Keep a manifest identifying which files are fabrication data shared across configurations and which are assembly-specific. When practical, include file hashes so a later check can distinguish the approved package from a similarly named replacement.
Regenerate into a clean output directory. Reusing a folder that contains last month’s files can leave an obsolete BOM beside the current placement data. Before sending the archive, open it as a recipient would and confirm that there is one clearly identified current set. Preserve older releases separately with their historical identity.
After a component substitution, repeat population and part-identity checks even if no copper changes. The replacement may affect package compatibility, orientation, test limits or purchasing scope. A small sourcing change is still a controlled release change when it changes what the assembler buys or places. Update the source and approval record before exporting another package.
Release checklist for fitted and DNP variants
- Identify the board revision, assembly revision, configuration and order quantity explicitly.
- Confirm the installed KiCad version and the behavior of the exporter actually used.
- Review changed references against an approved population matrix.
- Synchronize the board and investigate unexpected updates before export.
- Check fitted part identifiers, grouped references and per-board BOM quantities.
- Explain every difference between the BOM and machine-placement reference sets.
- Confirm coordinate origin, units, board side and rotation conventions with the assembler.
- Align assembly drawings, programming instructions and test expectations with the configuration.
- Open the final archive and verify that it contains one consistent, approved release.
For the broader handoff, review the BOM and placement-file requirements and the KiCad schematic-to-build workflow. When preparing prototype PCB fabrication, identify the shared bare board separately from each planned assembly. Send the configuration and build requirements for review with the files so the intended population is clear before quotation.